Template:Table/Dev:Semantic Constraints

From railML 3 Wiki
Jump to navigation Jump to search

Return to article

Element ID Proposal date Date of acception Date of deprecation Description
<TT:operationalTrainSectionPart> TT:001 2022-09-15 2022-10-13 There is always only a single successor and predecessor for an <operationalTrainSectionPart> in the chain of <operationalTrainSectionPart>s that are linked via the attribute @next.
<TT:operationalTrainVariant> TT:002 2023-01-12 2023-04-06 When calculating which <operationalTrainVariant> of an <operationalTrain> is valid on a particular day always a maximum of one active <operationalTrainVariant> shall be the result. If the result is more than one <operationalTrainVariant>, all except one shall be marked as <isCancelled> or <isOnRequest>.
<TT:commercialTrainVariant> TT:003 2023-01-12 2023-04-06 When calculating which <commercialTrainVariant> of an <commercialTrain> is valid on a particular day always a maximum of one active <commercialTrainVariant> shall be the result. If the result is more than one <commercialTrainVariant>, all except one shall be marked as <isCancelled> or <isOnRequest>.
<TT:operationalTrainSection> TT:004 2022-01-12 2023-03-09 The itinerary sections of an <operationalTrainVariant>, defined by the <operationalTrainSection>s and their respective <range>s, that are not <isCancelled> and not marked as <isOnRequest>, must be pairwise disjoint, except for their respective first and last <baseItineraryPoint>s.
<TT:operationalTrainSection> TT:005 2022-01-12 2023-03-09 The first(last) <baseItineraryPoint> of each <operationalTrainSection> within an <operationalTrainVariant> must either be the referenced <itinerary>'s first(last) <baseItineraryPoint>, or coincide with another section's last(first) <baseItineraryPoint>.
<TT:commercialTrainSection> TT:006 2022-01-12 2023-03-09 The itinerary sections of an <commercialTrainVariant>, defined by the <commercialTrainSection>s and their respective <range>s, that are not <isCancelled> and not marked as <isOnRequest>, must be pairwise disjoint, except for their respective first and last <baseItineraryPoint>s.
<TT:commercialTrainSection> TT:007 2022-01-12 2023-03-09 The first(last) <baseItineraryPoint> of each <commercialTrainSection> within an <commercialTrainVariant> must either be the referenced <itinerary>'s first(last) <baseItineraryPoint>, or coincide with another section's last(first) <baseItineraryPoint>.
<RTM:isValid>, <CO:validityTime:period> IS:001 2024-01-15 2024-02-26 ETCS WG

2024-03-22 SCTP WG

2024-04-15 NEST WG

Starting time stamp (e.g. "from") shall be lower or equal any ending time stamp (e.g. "to") if both are given. Must not overlap with other validity periods.
<IS:trainProtectionElement> IS:002 2021-02-26 2024-02-26 ETCS WG

2024-03-22 SCTP WG

2024-04-15 NEST WG

<trainProtectionElement> shall only be used for national and/or legacy train protection systems. ETCS-based systems must not be modeled using <trainProtectionElement>.
<IS:levelCrossingIS> IS:003 2023-10-23 2024-02-26 ETCS WG

2024-03-22 SCTP WG

2024-04-15 NEST WG

<levelCrossingIS> should not have a <crossesElement> child of type railway. This case should be represented either by a <crossing> in case of a simple crossing, or by a <switchIS> of type doubleSwitchCrossing or singleSwitchCrossing.
<IS:underCrossing>, <IS:overCrossing> IS:004 2023-10-23 was declined 2024-02-26 should only have a <crossesElement> child of type railway when railway crosses railway (not on the same level!).
<IS:signalConstruction> IS:005 2024-01-22 2024-03-22 SCTP WG

2024-04-15 NEST WG

@height and @positionAtTrack should not be used with @type=virtual.

<IS:line> IS:006 2024-01-29 2024-02-26 ETCS WG

2024-04-15 NEST WG

each line with own mileage should always be associated with its own <linearPositioningSystem>, i.e. Advanced example of railML has three lines with their own mileages, thus should have thee <linearPositioningSystem>s.

2024-03-22 SCTP WG - GUI implementation not clear

<IS:border> IS:007 2024-01-29 2024-08-09 SCTP WG

if @isOpenEnd="true" then @type should be set as @type="area".

<IS:netElement> IS:008 2024-02-02 2024-08-09 SCTP WG

Aggregation of net elements should follow the tree data structure. See figure below. This means that no two (mesoscopic) net elements can aggregate same (microscopic) net element. In other words, (microscopic) net element can be aggregated by at most one (mesoscopic) net element.

<IS:netElement> IS:009 2024-02-02 2024-08-09 SCTP WG

Linear (geometric) coordinates (explicit or implicit, e.g. calculated as a sum of the coordinate of beginning and the length of the net element) of the same place represented at different levels of aggregation should have the same value. In the figure below (linear) coordinate the coordinate of e.g. end of ne1 should be same as one of ne1.2.

<IS:netElement> IS:010 2024-02-26

Difference of linear coordinates if the beginning and end of <netElement>, represented by <intrinsicCoordinate> / @intrinsicCoord = 0 and 1 correspondingly, should equal the the @length of <netElement> if all are present in the data. For each case when a difference of linear coordinates if the beginning and end of <netElement>, represented by <intrinsicCoordinate> / @intrinsicCoord = 0 and 1 correspondingly, does not equal the the @length of <netElement> if all are present in the data, a <mileageChange> of <anchor> should be present explaining anomaly

<IS:netElement> IS:011 2024-02-29 2024-08-09 SCTP WG

Aggregation must not happen within the same level of detail. In the figure below, element 1.1 must not aggregate element 1.2. This means that aggregating and aggregated net elements must not be referred from the same <level>

<RTM:spotLocation> IS:012 2024-03-04 2024-04-19 SCTP WG

2024-05-13 ETCS WG

@pos should have only positive values because it's a distance, thus -1 is not a valid value

functional infrastructure and geometry entities IS:013 2024-03-25

there can be no two functional infrastructure or geometry entities of the same type located at the same coordinate of spot location, e.g. two railway switches or two gradient curves having the same linear coordinate make no sense. Except for the entities linked by the @belongsToParent attribute and railway crossing modelled as switch of type "doubleSwitchCrossing" and two railway switches of type "switchCrossingPart". wording will be improved

<RTM:linearPositioningSystem> IS:014 2024-04-08 2024-04-15 NEST WG

2024-04-19 SCTP WG

@startMeasure and @endMeasure are start and end values of a railway <IS:line> associated with <RTM:linearPositioningSystem> not max and min values of a current file with e.g. line section.

<IS:netRelation> IS:015 2024-04-22 2024-08-09 SCTP WG There must be no "inverse" net relations in the topology, i.e. if "nr1 elemeneA ne1", "nr1 elementB ne2" and "nr2 elemeneA ne2", "nr2 elementB ne1" then topology is not valid. See invalid code below.
<IS:gradientCurve> IS:016 2024-05-31 @gradient should not be used if @curveType="mixed". Instead of @gradient, @deltaGradient should be used.
<IS:trainProtectionElement> IS:017 2009-10-17 2009-10-17

Users can refer to the train protection system using the attribute @trainProtectionSystem that shall link to the codelist (link to the railML® website) TrainProtectionSystems.xml (link to the railML® website), section trainProtectionSystemsAtTrack. Only if this list does not contain the specific train protection system to be modelled, it shall be described in its functionality using attributes @medium and @monitoring.

<IS:opEquipment> IS:018 2024-08-26

Any functional infrastructure element that belongs to an <operationalPoint> may be listed as its equipment. This may be done by adding it to a specific container, such as <ownsPlatform>, <ownsTrack> and <ownsSignal> or it may be added to the generic container <ownsInfrastructureElement>. Any such added infrastructure element must be added to the most specific container available. No element shall be part of two such containers. If no specific container for the functional infrastructure element exists, it shall be listed in the generic container. Example: a <signalIS> must not be added to <ownsInfrastructureElement>. It shall be added to <ownsSignal>. As there is no container for levelCrossings a <levelCrossingIS> belonging to an <operationalPoint> shall be added to <ownsInfrastructureElement>.

<IS:infrastructureState> IS:019 2024-09-03 2024-09-13 SCTP WG

When calculating which <infrastructureState> of an <infrastructure> is valid on a particular time always a maximum of one active <infrastructureState> shall be the result. See examples below.

<IS:speedSection> IS:020 2022-04-25

Each railML® <speedSection> element must reference (at least) one global defined railML® <speedProfile> element.

<TT:times> TT:008 2024-11-21

No two attributes //<times>/@scope of the same enclosing stop/pass elements shall have the same value.

<TT:times> TT:008 2024-11-21

No two attributes //<times>/@scope of the same enclosing stop/pass elements shall have the same value.

<TT:times> TT:008 2024-11-21

No two attributes //<times>/@scope of the same enclosing stop/pass elements shall have the same value.