IL:powerSupplyIL

From railML 3 Wiki
Revision as of 18:51, 19 December 2019 by RailML Coord Documentation (talk | contribs) (Created page with "{{subst:docBase |element=powerSupplyIL |subschema=IL}}")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Introduction

Documentation

Syntax

Autoexport from the XML-Schema for element IL:powerSupplyIL of railML® version 3.2
Documentation specific features of power supply used for interlocking
Subschema interlocking
Parents* powerSuppliesIL
Children belongsToInfrastructureManager (0..1), belongsToOperationalPoint (0..1), designator (0..*), hasCommand (0..*), hasIndication (0..*), hasModeIndicator (0..1), hasName (0..*)
Attributes:
  • numberOfSimultaneousSwitchingActuators: maximum number of switch actuators that can be activated simultaneously with this power supply (optional; xs:nonNegativeInteger),

  • signalVoltageMode: normal mode of switching signal voltage for day and night voltage (optional; xs:string)
Possible values:
  • automatic: the switchover between the signal voltage levels (day/night) is done automatically
  • manual: the switchover between the signal voltage levels (day/night) is done manually
  • nightOnly: the signal voltage level is kept on night voltage
  • none: no steering of signal voltage levels,

  • elementNumber: element number of the asset for internal reference in engineering data (optional; xs:nonNegativeInteger),

  • model: The model name of the asset from the supplier. (optional; xs:string),

  • softwareVersion: The software version of the asset itself. (optional; xs:string),

  • id: unique identifier (obligatory; xs:string; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}}); compare: Dev:Identities
*Notice:
Elements may have different parent elements. As a consequence they may be used in different contexts.
Please, consider this as well as a user of this wiki as when developing this documentation further.
Aspects that are only relevant with respect to one of several parents should be explained exclusively in the documentation of the respective parent element.

Autoexport from the XML-Schema for element IL:powerSupplyIL of railML® version 3.1
Documentation specific features of power supply used for interlocking
Subschema interlocking
Parents* powerSuppliesIL
Children any (0..*), designator (0..1)
Attributes:
  • numberOfSimultaneousSwitchingActuators: maximum number of switch actuators that can be activated simultaneously with this power supply (optional; xs:nonNegativeInteger),

  • signalVoltageMode: mode of switching signal voltage for day and night voltage (optional; xs:string)
Possible values:
  • none
  • nightOnly
  • manual
  • automatic,

  • id: unique identifier (optional; xs:ID; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}}); compare: Dev:Identities
*Notice:
Elements may have different parent elements. As a consequence they may be used in different contexts.
Please, consider this as well as a user of this wiki as when developing this documentation further.
Aspects that are only relevant with respect to one of several parents should be explained exclusively in the documentation of the respective parent element.


Changes 3.1→3.2

The children have changed.

The attributes have been changed.

Semantics

Best Practice / Examples

Additional Information

Notes

Open Issues