CO:tractionMode/3.2: Difference between revisions

From railML 3 Wiki
Jump to navigation Jump to search
[checked revision][checked revision]
(Created page CO:tractionMode/3.2 using XSD2MediaWiki Converter 1.0.6)
 
(Updated page CO:tractionMode/3.2 using XSD2MediaWiki Converter 1.1.1)
 
Line 7: Line 7:
|version=3.2
|version=3.2
|parent={{parent|subschema=RS|name=trainEngine}}
|parent={{parent|subschema=RS|name=trainEngine}}
|attributes={{attribut|name=mode|pflicht=0|typ=xs:string|documentation=Mode of traction related to the ElectrificationSystem|werte={{wert|name=battery}}{{wert|name=diesel}}{{wert|name=electricOverheadLine}}{{wert|name=electricThirdRail}}{{wert|name=hydrogenFuelCell}}|patterns={{pattern|other:\w{2,}}}}},
|attributes={{attribut|name=isPrimaryMode|pflicht=0|typ=xs:boolean|documentation=Flag, whether this is the primary mode of traction of the train}},
{{attribut|name=isPrimaryMode|pflicht=0|typ=xs:boolean|documentation=Flag, whether this is the primary mode of traction of the train}},
{{attribut|name=mode|pflicht=0|typ=xs:string|documentation=Mode of traction related to the ElectrificationSystem|werte={{wert|name=battery}}{{wert|name=diesel}}{{wert|name=electricOverheadLine}}{{wert|name=electricThirdRail}}{{wert|name=hydrogenFuelCell}}|patterns={{pattern|other:\w{2,}}}}},
{{attribut|name=frequency|pflicht=0|typ=xs:decimal|documentation=electrification system frequency, in [Hz]; for DC the frequency shall be set to zero|minInclusive=0|fractionDigits=3}},
{{attribut|name=voltage|pflicht=0|typ=xs:decimal|documentation=electrification system voltage, in [V]|fractionDigits=1}},
{{attribut|name=voltage|pflicht=0|typ=xs:decimal|documentation=electrification system voltage, in [V]|fractionDigits=1}},
{{attribut|name=frequency|pflicht=0|typ=xs:decimal|documentation=electrification system frequency, in [Hz]; for DC the frequency shall be set to zero|minInclusive=0|fractionDigits=3}},
{{attribut|name=id|pflicht=1|typ=xs:string|documentation=unique identifier|patterns={{pattern|(urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|\{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}\}}}}}
{{attribut|name=id|pflicht=1|typ=xs:string|documentation=unique identifier|patterns={{pattern|(urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|\{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}\}}}}}
}}
}}

Latest revision as of 12:43, 8 February 2024

Automatic Schemaexport for Element tractionMode

Autoexport from the XML-Schema for element CO:tractionMode of railML® version 3.2
Documentation The particular traction mode of the system within the complete formation, where these data are valid.
Subschema common
Parents* trainEngine
Children None
Attributes:
  • isPrimaryMode: Flag, whether this is the primary mode of traction of the train (optional; xs:boolean),

  • mode: Mode of traction related to the ElectrificationSystem (optional; xs:string; patterns: other:\w{2,})
Possible values:
  • battery
  • diesel
  • electricOverheadLine
  • electricThirdRail
  • hydrogenFuelCell,

  • frequency: electrification system frequency, in [Hz]; for DC the frequency shall be set to zero (optional; xs:decimal; minInclusive: 0; fractionDigits: 3),

  • voltage: electrification system voltage, in [V] (optional; xs:decimal; fractionDigits: 1),

  • id: unique identifier (obligatory; xs:string; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|\{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}\}); compare: Dev:Identities
*Notice:
Elements may have different parent elements. As a consequence they may be used in different contexts.
Please, consider this as well as a user of this wiki as when developing this documentation further.
Aspects that are only relevant with respect to one of several parents should be explained exclusively in the documentation of the respective parent element.