IS:electrificationSection/3.1: Difference between revisions

From railML 3 Wiki
Jump to navigation Jump to search
[unchecked revision][checked revision]
No edit summary
(Updated page IS:electrificationSection/3.1 using XSD2MediaWiki Converter 1.0.2)
 
Line 6: Line 6:
|version=3.1
|version=3.1
|parent={{parent|subschema=IS|name=electrifications}}
|parent={{parent|subschema=IS|name=electrifications}}
|children={{child|subschema=CO|name=electrificationSystemRef|multiplicity=0..1}}, {{child|subschema=IS|name=energyCatenary|multiplicity=0..1}}, {{child|subschema=IS|name=energyPantograph|multiplicity=0..1}}, {{child|subschema=IS|name=energyRollingstock|multiplicity=0..1}}, {{child|subschema=IS|name=hasContactWire|multiplicity=0..1}}, {{child|subschema=IS|name=pantographSpacing|multiplicity=0..*}}, {{child|subschema=IS|name=phaseSeparationSection|multiplicity=0..*}}, {{child|subschema=IS|name=systemSeparationSection|multiplicity=0..*}}, {{child|subschema=CO|name=designator|multiplicity=0..*}}, {{child|subschema=CO|name=external|multiplicity=0..*}}, {{child|subschema=IS|name=gmlLocations|multiplicity=0..*}}, {{child|subschema=IS|name=networkLocation|multiplicity=0..*}}, {{Any}}, {{child|subschema=RTM|name=areaLocation|multiplicity=0..*}}, {{child|subschema=RTM|name=linearLocation|multiplicity=0..*}}, {{child|subschema=RTM|name=spotLocation|multiplicity=0..*}}, {{child|subschema=RTM|name=isValid|multiplicity=0..*}}, {{child|subschema=CO|name=name|multiplicity=0..*}}
|children={{Any|multiplicity=0..*}}, {{child|subschema=RTM|name=areaLocation|multiplicity=0..*}}, {{child|subschema=CO|name=designator|multiplicity=0..*}}, {{child|subschema=CO|name=electrificationSystemRef|multiplicity=0..1}}, {{child|subschema=IS|name=energyCatenary|multiplicity=0..1}}, {{child|subschema=IS|name=energyPantograph|multiplicity=0..1}}, {{child|subschema=IS|name=energyRollingstock|multiplicity=0..1}}, {{child|subschema=CO|name=external|multiplicity=0..*}}, {{child|subschema=IS|name=gmlLocations|multiplicity=0..*}}, {{child|subschema=IS|name=hasContactWire|multiplicity=0..1}}, {{child|subschema=RTM|name=isValid|multiplicity=0..*}}, {{child|subschema=RTM|name=linearLocation|multiplicity=0..*}}, {{child|subschema=CO|name=name|multiplicity=0..*}}, {{child|subschema=IS|name=networkLocation|multiplicity=0..*}}, {{child|subschema=IS|name=pantographSpacing|multiplicity=0..*}}, {{child|subschema=IS|name=phaseSeparationSection|multiplicity=0..*}}, {{child|subschema=RTM|name=spotLocation|multiplicity=0..*}}, {{child|subschema=IS|name=systemSeparationSection|multiplicity=0..*}}
|attributes={{attribut|name=contactLineType|pflicht=1|typ=xs:string|documentation=type of the installed contact line (most common: overhead)|werte={{wert|name=3rdRailTop}}{{wert|name=3rdRailSide}}{{wert|name=3rdRailBottom}}{{wert|name=sideRail}}{{wert|name=overhead}}{{wert|name=none}}}},
|attributes={{attribut|name=contactLineType|pflicht=1|typ=xs:string|documentation=type of the installed contact line (most common: overhead)|werte={{wert|name=3rdRailTop}}{{wert|name=3rdRailSide}}{{wert|name=3rdRailBottom}}{{wert|name=sideRail}}{{wert|name=overhead}}{{wert|name=none}}}},
{{attribut|name=isInsulatedSection|pflicht=0|typ=xs:boolean|documentation=set true if the described electrification section is an insulated section}},
{{attribut|name=isInsulatedSection|pflicht=0|typ=xs:boolean|documentation=set true if the described electrification section is an insulated section}},

Latest revision as of 13:21, 24 January 2020

Automatic Schemaexport for Element electrificationSection



Autoexport from the XML-Schema for element IS:electrificationSection of railML® version 3.1
Documentation This element is not documented in the schema!
Subschema infrastructure
Parents* electrifications
Children any (0..*), areaLocation (0..*), designator (0..*), electrificationSystemRef (0..1), energyCatenary (0..1), energyPantograph (0..1), energyRollingstock (0..1), external (0..*), gmlLocations (0..*), hasContactWire (0..1), isValid (0..*), linearLocation (0..*), name (0..*), networkLocation (0..*), pantographSpacing (0..*), phaseSeparationSection (0..*), spotLocation (0..*), systemSeparationSection (0..*)
Attributes:
  • contactLineType: type of the installed contact line (most common: overhead) (obligatory; xs:string)
Possible values:
  • 3rdRailTop
  • 3rdRailSide
  • 3rdRailBottom
  • sideRail
  • overhead
  • none,

  • isInsulatedSection: set true if the described electrification section is an insulated section (optional; xs:boolean),

  • belongsToParent: reference to the (one and only) parent electrification section (optional; xs:IDREF; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|\{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}\}),

  • id: the identifier of the object; this can be either of type xs:ID or UUID (obligatory; xs:ID; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|\{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}\}); compare: Dev:Identities
*Notice:
Elements may have different parent elements. As a consequence they may be used in different contexts.
Please, consider this as well as a user of this wiki as when developing this documentation further.