Autoexport from the XML-Schema for element IL:stationIndicator of railML® version 3.2
Documentation Individual virtual logical object used for indication and commanding of station related groups or zones on HMI
Subschema interlocking
Parents* stationIndicators
Children belongsToOperationalPoint (0..1), designator (0..*), hasCommand (0..*), hasIndication (0..*)
Attributes:
  • usedFor: defines the use of this indicator for a particular station zone or group of elements represented by this zone (obligatory; xs:string; patterns: other:w{2,})
Possible values:
  • automaticRouteSetting: defined operational zone for enabling/disabling of automatic route setting mode
  • automaticTrainRouting: defined operational zone for enabling/disabling of automatic train routing mode
  • catenary: control of a collection of catenary sections
  • doorAlarm: control of a collection of door/intrusion detectors
  • emergencyStopGroup: control of a collection of signals applicable for emergency stop command
  • errors: control of element error indicators
  • fireAlarm: control of a collection of fire detectors
  • handCrank: control of a collection of hand cranks
  • inhibitionCheck: control of inhibition status a collection of elements
  • keylockIndicator: control of a collection of key locks
  • operatingArea: control of predefined area within a station to operate from different operator places
  • operatingGroup: control of a collection of operating areas
  • operatingMode: control of operating permissions for an operating area – centrally/locally operated
  • overallOperatingMode: control of operating permissions for all operating areas of the related signal box/interlocking – centrally/locally operated
  • powerSupplyMode: control of power supply for signal voltage levels
  • switchHeating: control of a collection of switch heating devices
  • switchHeatingTemperatureSensor: control of a collection of switch heating temperature sensors
  • switchPositionIndicator: control of a collection of switch position indicators
  • switchStaggering: control of a switch staggering group
  • temperatureAlarm: control of a collection of temperature detection,

  • elementNumber: number of the element in the set of interlocking data (optional; xs:nonNegativeInteger),

  • id: unique identifier (obligatory; xs:string; patterns: (urn:uuid:)?[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}|{[0-9a-fA-F]{8}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{4}-[0-9a-fA-F]{12}}); compare: Dev:Identities
*Notice:
Elements may have different parent elements. As a consequence they may be used in different contexts.
Please, consider this as well as a user of this wiki as when developing this documentation further.
Aspects that are only relevant with respect to one of several parents should be explained exclusively in the documentation of the respective parent element.

This element does not appear in railML® 3.1 within the IL subschema. It is available only in railML® 3.2. Do not hesitate to contact railML.org for further questions.


Changes 3.1→3.2

Introduced with version 3.2.

Semantics

Best Practice / Examples

Additional Information

Notes