|documentation= | |documentation=a section of a contact network without electrical voltage, intended for electrical isolation of its sections charged with electricity from each other or from large structures, ensuring unhindered movement of the rolling stock pantograph between them [Wikipedia]. This is in particular a border between electrification systems e.g. AC and DC. | ||
|version=3.2 | |version=3.2 | ||
|parent={{parent|subschema=IS|name=electrificationSection}} | |parent={{parent|subschema=IS|name=electrificationSection}} | ||
|attributes={{attribut|name= | |attributes={{attribut|name=isSupplySystemChange|pflicht=0|typ=xs:boolean|documentation=flag, whether the supply system changes at the separation}}, | ||
{{attribut|name= | {{attribut|name=lengthSystemSeparation|pflicht=0|typ=xs:decimal|documentation=length of the system separation section in contact line, in [m]}}, | ||
{{attribut|name=lowerPantograph|pflicht=0|typ=xs:boolean|documentation=flag, whether the pantographs have to be lowered when passing the system separation}}, | {{attribut|name=lowerPantograph|pflicht=0|typ=xs:boolean|documentation=flag, whether the pantographs have to be lowered when passing the system separation}}, | ||
{{attribut|name= | {{attribut|name=switchOffBreaker|pflicht=0|typ=xs:boolean|documentation=flag, whether the main circuit breaker has to be switched off when passing the system separation}} | ||
}} | }} |
Latest revision as of 12:49, 25 November 2024
Automatic Schemaexport for Element systemSeparationSection
Autoexport from the XML-Schema for element IS:systemSeparationSection of railML® version 3.2 | |
Documentation | a section of a contact network without electrical voltage, intended for electrical isolation of its sections charged with electricity from each other or from large structures, ensuring unhindered movement of the rolling stock pantograph between them [Wikipedia]. This is in particular a border between electrification systems e.g. AC and DC. |
Subschema | infrastructure |
Parents* | |
Children |
None |
Attributes:
| |
*Notice: Elements may have different parent elements. As a consequence they may be used in different contexts. Please, consider this as well as a user of this wiki as when developing this documentation further. Aspects that are only relevant with respect to one of several parents should be explained exclusively in the documentation of the respective parent element. |